Most variants in the supplied datasheet provide 500+ cleaning cycles. SC PRO and LC PRO are listed at 775+ cleaning cycles.
FAQ’s
The datasheet lists 288 fibers in the LC-MTP® configuration and 1,152 fibers in the 4×MTP®-MTP® configuration, calculated at 12 fibers per MTP connector. The older introductory paragraph says up to 288 fibers, so the public page should present the detailed specification values while flagging the source inconsistency for QA.
The datasheet lists 72 modules, and the mechanical drawing title also states ‘up to 72 modules’.
The detailed specification table lists 192 MTP® ports in the 4×MTP®-MTP® configuration, corresponding to 2,304 fibers at 12 fibers per connector.
The datasheet lists 36 modules. The mechanical drawing title states the enclosure is designed for up to 24 modules, which conflicts with the datasheet and should be resolved by Fibernet Engineering before publication of a definitive maximum.
The datasheet lists a total of 8 modules, and the mechanical drawing title also states that the 1U fixed 19-inch panel supports up to 8 modules.
The OPM8 stores more than 1,000 results in AFL .ATD (XML) format and supports transfer for analysis and reporting.
The enclosure contains two trays. Each tray can be pulled out individually for easier access to ports and patch cords.
The published specification lists two trays.
The published datasheet specifies six pull-out trays for easier access to cables, ports and patch cords.
The published datasheet specifies 12 pull-out trays for easier access to cables, ports and patch cords.
The datasheet lists 12 trunk cable positions with strain-relief clips for secure mounting.
The published datasheet lists 96 fibers with LC-MTP® modules, 384 fibers with 4×MTP®-MTP® modules, and up to 576 fibers with 6×MTP®-MTP® modules.
The specification lists storage for 10,000 files, with result-storage capacity of 1,000 multi-fiber results and 1,500 single-fiber results.
Yes. The supplied Fibernet product-page text specifically states that the kit is intended for use with STAR Fusion Splice Modules.
Yes. The product description positions the kit as an accessory used to support operation of the Fibernet STAR high-density solution.
The supplied datasheet states that the MTP® PRO Tool is compatible with MTP® PRO connectors only.
No dimensions or material specifications are provided in the supplied source. These values should not be published until a datasheet is available.
The datasheet lists 482.8 mm width and 530 mm depth. The mechanical drawing shows an 88.90 mm (2U) height and additional body dimensions. The datasheet specification table incorrectly prints 1U for height, so the mechanical drawing should be treated as the controlling dimensional reference pending Engineering confirmation.
The mechanical drawing shows 43.7 mm height, 482.0 mm overall 19-inch rack width and 238.3 mm depth. The datasheet lists a 442 mm enclosure width and 238 mm depth; the drawing distinguishes the chassis from the rack ears.
The published dimensions are 1U height, 482.8 mm width and 488.8 mm depth. The enclosure is black RAL 9005.
The mechanical drawing shows a 4U height of 178.0 mm and a 19-inch mounting width of 482.6 mm. The datasheet lists 482.8 mm width and 530 mm depth, while the drawing shows a 518.3 mm chassis depth. The datasheet height field incorrectly prints 1U, so Fibernet should use the mechanical drawing as the dimensional reference pending final Engineering approval.
The datasheet lists 7.9 × 5.1 × 2.2 cm and 43 g.
Both models use one AA battery. The datasheet lists less than 30 hours in flash mode for VFI4 and less than 50 hours for VFI4-L.
The tool is designed to change field polarity and to support field pin removal/reconfiguration from male to female and from female to male.
The supplied product-page screenshot does not provide a component list. A datasheet or engineering bill of materials is required before publishing exact kit contents.
Strong external light can cause false Traffic detection. The FID-30R indicates this condition by illuminating direction triangles on both sides of the LCD so the operator can shield the clamp head from the external light source.
The supplied FS200 datasheet lists model-dependent dynamic range up to 37 dB.
The supplied product-page screenshot does not specify supported fiber counts. This should be confirmed from the product datasheet or Fibernet Engineering.
A One-Click™ cleaner is a dry, push-type optical connector cleaning tool designed to remove contaminants from fiber connector end faces with a single-push action.