The supplied range includes the One-Click™ Cleaner MPO for MPO/MTP™ connectors, the MPO-16 for 16f/32f MPO connectors, and the MPO ESD for 12f/24f MPO or MTP® connectors.
FAQ’s
The One-Click™ Cleaner SC and SC Mini are listed for SC/ST/FC connectors. The M250 is also listed for SC applications, while HOC supports TITAN/TRIDENT™/SC.
The included 2.5 mm universal adapter accepts connectors such as FC, SC and ST. The VFI4 High Power version also includes a 1.25 mm universal adapter for LC and MU connectors.
The clamp head supports 250 µm single fiber through 3000 µm jacketed cord and up to 12-fiber ribbon without changing clamp heads.
The datasheet lists qualifications and test-method compliance including TIA-568.3-E, TIA-526-7, TIA-526-14, IEC 11801, IEC 14763-3 and IEC 61280-4-1/-4-2, with encircled-flux conditions noted for some multimode tests.
The standards section references bend-insensitive OM3, OM4 and single-mode G.657.A2 fiber.
For detailed single-mode links, FS200 is suitable. For environments that require both multimode and single-mode testing, the FS300 Quad OTDR is the stronger fit because it combines both fiber types and supports OTDR, insertion-loss and reporting workflows.
Automated analysis supports IEC 61300-3-35 (2015), AT&T TP-76461, IPC-8497-1 and user-defined inspection criteria.
The supplied source lists Normal, Fast and Fine measurement modes so the operator can adjust the measurement according to the application and line conditions.
The product is documented for MPO-8, MPO-12, MPO-16, MPO-24 and MPO-32 connectors, including single-row and multi-row connector formats.
The datasheet lists OLS8-QUAD for multimode and single-mode testing, OLS8-SM for 1310/1550 nm single-mode testing, and OLS8-XGS for 1310/1550/1490 nm XGS/PON-related testing.
The datasheet lists OPF2004, OPF2005, OPF2006 and OPF2007 for female/male pin exchangers in aqua and yellow.
The tool is intended for MTP® PRO connectors. On the Fibernet site, the MTP® PRO Patch Cord is the directly related product shown with this tool kit.
The datasheet lists CE marking, IEC/EN 61010-1, IEC/EN 61326-1, EN 55011, FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1, and RoHS 2 / RoHS 3 compliance.
The built-in FID-30R power meter measures Traffic signals at 1310, 1490 and 1550 nm, as well as modulated Tone signals including 270 Hz, 330 Hz, 1 kHz and 2 kHz.
The OPM8 is calibrated at 850, 980, 1270, 1300, 1310, 1490, 1550, 1577, 1610, 1625 and 1650 nm.
Contamination on the ferrule end face can contribute to optical loss and connection problems. The supplied One-Click™ cleaner documentation is designed around removing dust, grease and other contaminants from connector end faces.
Yes. The datasheet lists insertion-loss, return-loss and interferometer testing of ferrule geometry for every fiber. It also lists verification of radius of curvature, tilt and fiber height.
Yes. The datasheet states that the product is compatible with all STAR ODF series products.
Yes. The datasheet states that insertion loss and return loss are tested for each fiber, and that IL/RL and ferrule-geometry testing are documented for every fiber.
The datasheet references IEEE 802.3ba for 40 Gb/s and 100 Gb/s and describes the family as supporting 10G/40G/100G migration solutions. Final link suitability should be validated against the selected fiber type, transceivers, connector architecture and optical loss budget.
Yes. The datasheet states that colored latches are available for network identification, with 12 colors listed in the product features and ordering system.
Yes. The MTP® PRO tool is described as supporting field pin removal and reconfiguration from male to female and from female to male.
Yes. The datasheet states that the MTP® PRO tool provides a one-step, color-coded polarity change without removing the connector housing.
Yes. The product is designed for reversible polarity in the field, allowing polarity changes during moves, adds and changes without replacing the patch cord.
Yes. The product architecture shown in the Fibernet datasheet places conversion harnesses between 8-fiber transceiver interfaces and existing 12-fiber MTP® trunk cabling through STAR MTP® modules. This allows the trunk layer to remain in service while the end connectivity is adapted.
The Fibernet datasheet lists IEEE 802.3ba for 40 Gb/s and 100 Gb/s and IEEE 802.3bs for 400 Gb/s among the referenced standards. Actual link suitability depends on the selected fiber type, transceiver interface, polarity, connector configuration and optical link budget.
Yes. The datasheet describes tool-free cable maintenance, and the optional latch pull tab allows the connector to be disengaged from densely loaded panels without special tools.
The latch pull tab provides a grip point for releasing the LC connector from densely populated panels, helping technicians remove the connection without reaching directly around the connector body or using a special extraction tool.
The product family supports configurations from 12 fibers up to 144 fibers, using single-mode or multimode fiber options.