Yes. The product-family features state that the cleaners can clean both APC and PC connector end faces. Individual model compatibility still depends on the connector type.
FAQ’s
Yes. Fujikura states that the instruments detect Tone, Traffic and ONU signals without interrupting the light by bending the coated fiber.
Yes. The OPM8 evaluates measured power or loss against user-defined minimum and maximum limits and displays color-coded pass/fail results.
Yes. The supplied FS300 Quad OTDR datasheet supports multimode point-to-point testing as well as single-mode point-to-point and PON testing up to 1:64.
Yes. The documented purpose of the tool is to change field polarity on compatible MTP® PRO connectors.
Yes. The source states that polarity is reversible in the field, supporting faster moves, adds and changes.
The supplied source only documents use with STAR Fusion Splice Modules. Compatibility with other products is not confirmed in the source provided.
Yes. Multi-fiber adapter tips are available for inspection of connectors and bulkheads with PC/UPC or APC polished end faces.
Yes. The source explicitly lists field pin removal from female to male as one of the supported functions.
Yes. The source explicitly lists field pin removal from male to female as one of the supported functions.
Yes. The supplied TS100 datasheet specifies TS100-70 for testing through splitters up to 1:64. TS100-60 is specified for testing to the splitter.
AFL specifically positions the VFI4 as a complement to OTDR testing because visible light can reveal faults inside an OTDR dead zone.
Yes. The supplied product-variation table lists ONU Detection for both FID-30R and FID-31R. Fujikura also notes that not every ONU can necessarily be detected.
Yes. TS100, FS200 and FS300 use LinkMap color-coded event displays to simplify interpretation of network health and pass/fail results.
The TS100 includes VFL, OLS and OPM functions. FS200 and FS300 configurations can include integrated or optional source and power-meter functions depending on the selected model and kit; both families include VFL capability in the supplied datasheets.
Yes. AFL describes the system for inspection of MPO and MTP® multi-fiber connectors and bulkheads when the appropriate adapter tip is used.
Yes. It is designed for untethered operation using a rechargeable battery and integrated 3.5-inch color touchscreen.
Yes. The datasheet states that the LC Uniboot Patch Cord includes a latch pull tab that helps disengage the connector from densely loaded panels without special tools.
Yes. The supplied datasheet states that the MTP® adapters have shutters.
Yes. The optical specification lists 2 Hz modulation or CW (continuous-wave) operation.
The source lists verification tests for insertion loss, return loss, radius of curvature, tilt and fiber height, and also states that ferrule geometry is checked by interferometer for every fiber.
The source states that insertion loss and return loss are 100% tested for each fiber, and that IL/RL and ferrule-geometry testing are documented for every fiber.
Results can be shared through USB-C and, on wireless models, Bluetooth. AFL also supports workflows using FlexApp and FlexReports for transfer, archiving and report generation.
The source specifies custom sleeve labeling plus colored latches, with 12 latch colors available for network identification.
Provide Fibernet with the STAR Fusion Splice Module, loose-tube cable construction and project configuration so the appropriate kit can be confirmed.
AFL states that the system can capture and display the entire MPO end-face image in less than two seconds and can perform cleanliness analysis at about one second per fiber.
Most variants in the supplied datasheet provide 500+ cleaning cycles. SC PRO and LC PRO are listed at 775+ cleaning cycles.
The supplied Fibernet datasheet lists 8-fiber and 12-fiber configurations.
The datasheet introduction states capacity up to 144 fibers and the mechanical specification table includes values through 144 fibers. However, the Build Your Order matrix shows Base-8 quantities up to 12×8 fibers, or 96 fibers. This source inconsistency should be resolved before publishing one definitive maximum for every configuration.
The module provides individual numbering for either 8 LC simplex connections or 4 LC duplex connections.