Reduce Cable Congestion
A single 2 mm cable carries both fibers, with the datasheet stating up to 50% cabling-volume savings.
Dense fiber panels can become difficult to route, identify and service when conventional duplex patch cords consume too much pathway space. The Fibernet LC Uniboot design places two fibers into one 2 mm patch cord, reducing cable volume while maintaining duplex LC connectivity.
The product also supports field-reversible polarity and custom identification through colored latches and sleeve labels, helping technicians perform faster moves, adds and changes in high-density environments.
Duplex Uniboot Optical Patch Cord with two fibers in a single jacket. Multimode OM3 50µm Bend-Insensitive fiber, terminated on both ends with duplex LC-Uniboot connectors featuring reversible polarity, factory UPC polished, 1 meter in length. Available in 12 identification colors according to project requirements.
Additional 1-meter length for the OM3 50µm Bend-Insensitive patch cord, in accordance with the standard.
A single 2 mm cable carries both fibers, with the datasheet stating up to 50% cabling-volume savings.
Reversible polarity supports quicker MAC work without replacing the patch cord when the required A/B orientation changes.
A compact connector design and latch pull-tab option help technicians access densely loaded LC panels without special tools.
Colored latches and custom sleeve labeling support clearer network identification and maintenance workflows.
Ordering example: FUG-9999UU0010-R — OM4 bend-insensitive fiber, LC-LC on both sides, UPC/UPC, 1 m cable length, Cross polarity, Red latch.
| Parameter | Multimode | Single-Mode |
|---|---|---|
| LC Connection Insertion Loss | 0.1 dB typical; 0.15 dB maximum | 0.1 dB typical; 0.15 dB maximum |
| Connector Repeatability – Loss Increase | <0.1 dB | <0.1 dB |
| Fiber Attenuation | <3.0 dB/km @ 850 nm | <0.35 dB/km @ 1310/1550 nm |
| Fiber Max. Bending Radius | 7.5 mm | 7.5 mm max. |
| Cable Max. Bending Radius | 10 mm | 7.5 mm max. |
| Operating Temperature | -20°C to +70°C | -20°C to +70°C |
| Cable Retention | 60 N | 60 N |
| Connector Retention | 60 N | 60 N |
| Temperature Cycling – Insertion Loss Variation | <0.1 dB | <0.1 dB |
| Vibration – Insertion Loss Variation | <0.1 dB | <0.1 dB |
| Retention – Insertion Loss Variation | <0.1 dB | <0.1 dB |
The source datasheet prints return-loss values with negative-sign notation. Those values are intentionally not reproduced in this production table until Fibernet Engineering confirms the intended published notation.
Dense LC duplex patching where pathway space, accessibility and polarity management matter.
Panels and cabinets where reduced cable bulk improves routing and technician access.
Compact duplex fiber patching for storage-network connections.
LC duplex interconnects requiring organized labeling and serviceability.
The datasheet cites deployment in disaster recovery, business continuity and central data-center sites.
The supplied datasheet references the following standards and compliance families: