Inspect Multi-Fiber Connectors Faster
Capture the full MPO end face in under two seconds and analyze cleanliness at approximately one second per fiber.
High-density fiber links depend on clean, correctly prepared connector end faces. A contaminated MPO/MTP® interface can affect multiple fibers at once, making visual inspection and documented cleanliness verification an important part of installation, turn-up and troubleshooting.
FOCIS Lightning®2 combines image capture, auto-focus, auto-centering and pass/fail analysis in a handheld platform. AFL states that it can capture and display an entire MPO end face in less than two seconds, helping technicians shorten the time between inspection and corrective action.
Wireless kit, soft case, USB cable, no tips or One-Click cleaner
Wireless kit + UPC ferrule/bulkhead adapter tip + 2 One-Click MPO cleaners
Wireless kit + APC ferrule/bulkhead adapter tip + 2 One-Click MPO cleaners
Wireless kit + UPC and APC tips + 2 One-Click MPO cleaners
Wireless kit + UPC/APC tips + 2 cleaners + single-fiber adapter
No-wireless kit, soft case, USB cable, no tips or cleaner
No-wireless kit + UPC tip + 2 One-Click MPO cleaners
Capture the full MPO end face in under two seconds and analyze cleanliness at approximately one second per fiber.
Use auto-focus, auto-centering and automated pass/fail analysis based on industry or user-defined criteria.
The integrated touchscreen and rechargeable battery allow the probe to operate independently without a separate display.
Store images and results locally, then transfer data through USB-C or Bluetooth workflows for archiving and reporting.
The system supports both multi-fiber and single-fiber inspection using interchangeable front-end tips. AFL documents support for MPO-8, -12, -16, -24 and -32, including single-row and multi-row formats.
Live-fiber note: AFL specifies a maximum no-damage live-fiber power level of +20 dBm, but states that the image cannot be viewed while the fiber is live.
| Parameter | Published Specification |
|---|---|
| Manual Detection Capability | 0.25 µm minimum |
| Auto Analysis Resolution | <1.0 µm |
| Focus | Auto-focus and manual focus |
| Centering | Auto-centering of captured single-fiber images |
| Live Zoom | 1x / 2x / 4x / 8x |
| Pass/Fail Analysis | IEC 61300-3-35 (2015), AT&T TP-76461, IPC-8497-1, user-set criteria |
| File Formats | JPG, GIF |
| File Storage Capacity | 10,000 files |
| Result Storage Capacity | Multi-fiber: 1,000; Single fiber: 1,500 |
| USB | USB-C; charging and USB 2.0 mass-storage device |
| Wireless | Bluetooth on wireless models |
| Operating Temperature | 0°C to +50°C |
| Storage Temperature | -40°C to +70°C |
| Relative Humidity | 0 to 95% RH |
| Transit Drop | 300 mm without soft case; 460 mm with soft case |
| Display | 3.5-inch color TFT touchscreen, 320 × 480 pixels |
| Battery | User-replaceable Li-Pol |
| Operating Time | 8 hours typical; 5 hours continuous |
| Size | 67 × 32 × 190 mm |
| Weight | 280 g |
| AFL No. | Kit Configuration |
|---|---|
| FOCIS-LT2-N | Wireless kit, soft case, USB cable, no tips or One-Click® cleaner |
| FOCIS-LT2-U | Wireless kit + UPC ferrule/bulkhead adapter tip + 2 One-Click MPO cleaners |
| FOCIS-LT2-A | Wireless kit + APC ferrule/bulkhead adapter tip + 2 One-Click MPO cleaners |
| FOCIS-LT2-UA | Wireless kit + UPC and APC tips + 2 One-Click MPO cleaners |
| FOCIS-LT2-UASF | Wireless kit + UPC/APC tips + 2 cleaners + single-fiber adapter |
| FOCIS-LT2-NW-N | No-wireless kit, soft case, USB cable, no tips or cleaner |
| FOCIS-LT2-NW-U | No-wireless kit + UPC tip + 2 One-Click MPO cleaners |
| FOCIS-LT2-NW-A | No-wireless kit + APC tip + 2 One-Click MPO cleaners |
| FOCIS-LT2-NW-UA | No-wireless kit + UPC/APC tips + 2 One-Click MPO cleaners |
| FOCIS-LT2-NW-UASF | No-wireless kit + UPC/APC tips + 2 cleaners + single-fiber adapter |
AFL provides interchangeable adapter tips for multiple MPO/MTP®, MMC, OptiTip and LC connector/bulkhead configurations.
| Part Number | Application | Tip ID |
|---|---|---|
| FLTNG-01-M12A | MPO-12/24 APC bulkhead, keyed | M12A |
| FLTNG-01-M12U | MPO-12/24 UPC bulkhead, keyed | M12U |
| FLTNG-01-M16U | MPO-16/32 UPC bulkhead, keyed | M16U |
| FLTNG-01-MPOA | MPO-12/16/24/32 APC bulkhead, no key | MPOA |
| FLTNG-01-MPOU | MPO-12/16/24/32 UPC bulkhead, no key | MPOU |
| FLTNG-01-MAC | MPO-12/16/24/32 APC connector, keyed | MAC |
| FLTNG-01-MUC | MPO-12/16/24/32 UPC connector, keyed | MUC |
| FLTNG-01-OPTM | OptiTip male pinned connector | OPTM |
| FLTNG-01-OPTF | OptiTip female unpinned connector | OPTF |
| FLTNG2-01-SFC | Coupler for most FFLX single-fiber connector adapter tips | SFC |
| FLTNG-01-ALCM | Extended LC-APC bulkhead adapter | ALCM |
| FLTNG-01-ULCM | Extended LC-UPC bulkhead adapter | ULCM |
| FLTNG-01-MPE | MPO extender barrel | MPE |
| FLTNG2-01-LVU | Large Field of View UPC adapter | LVU |
Inspect high-density MPO/MTP® links during installation, turn-up and troubleshooting.
Confirm whether cleaning actions produced an end face that meets the selected analysis criteria.
Inspect hardened connectors used in access and FTTx network environments.
Pair connector inspection results with broader fiber test workflows and AFL reporting tools.